Sale! View larger

ST-16-006 -- Evaluation of Refrigerant Mixtures in Three Different Cold-Climate Residential Air-Source Heat Pumps

New product

ST-16-006 -- Evaluation of Refrigerant Mixtures in Three Different Cold-Climate Residential Air-Source Heat Pumps

Conference Proceeding by ASHRAE, 2016

A. Hakkaki-Fard, PhD; Z. Aidoun, PhD; P. Eslami-Nejad,PhD

More details

$6.45

-57%

$15.00

More info

Full Description

This paper addresses the challenge of improving the performance of heat pumps (HPs) in cold-climate conditions by applying refrigerant mixtures. The potential benefits of implementing R-32/CO2 zeotropic refrigerant mixtures in three different residential air-source HPs for cold climates are studied. The cases considered are conventional residential HP, HP with a variable mixture control system, and HP with a variable compressor speed. The seasonal performance of a heating system with these air-source HPs, supplemented with an auxiliary electric heater, is studied in the cold-climate city of Montreal, Canada. To this aim, a detailed screening HP model previously developed is modified and used. The obtained results highlight the potential HP performance improvement of applying refrigerant mixtures.

Citation: 2016 Annual Conference, St. Louis, MO, Transactions 2016, Vol 122 pt. 2

Product Details

Published: 2016 Number of Pages: 8Units of Measure:DualFile Size: 1 file , 3.3 MB Product Code(s): D-ST-16-006