View larger
New product
standard by ASTM International, 04/01/2013
Warning: Last items in stock!
Availability date:
1.1This procedure covers the determination of Bisphenol A (BPA) in soil, sludge, and biosolids. This test method is based upon solvent extraction of a soil matrix by pressurized fluid extraction (PFE). The extract is filtered and analyzed by liquid chromatography/tandem mass spectrometry (LC/MS/MS). BPA is qualitatively and quantitatively determined by this test method.
1.2Units-The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3The Method Detection Limit2 (MDL), electrospray ionization (ESI) mode, and Reporting Range3 for BPA are listed in Table 1.
TABLE 1 Method Detection Limit and Reporting Range| Analyte | ESI Mode | MDL (PPB) | Reporting Range (PPB) |
| Bisphenol A | Negative | 2.8 | 10-250 |
1.4This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.